The Builder recommended every installed tool as ready to use without
ever checking whether its provider actually has credentials configured.
A credentialed tool with no tool_builtin_providers row got bound into a
plan and then failed at test time with an authorization error the user
can't act on.
tool_catalogue.py now carries provider_controller.need_credentials onto
each ToolCatalogueEntry as needs_credentials. resources.py resolves
which providers are actually authorized for the tenant (mirroring
ToolTransformService.builtin_provider_to_user_provider's need_credentials
/ db_provider rule exactly, so the Builder and the console's tools page
can never disagree) and sets ResourceRef.readiness to "missing_config"
for a credentialed tool with no authorized provider row, "ready"
otherwise. Datasets and models are unaffected. If the authorization
query itself fails, readiness fails open to "ready" rather than
mass-labeling every credentialed tool unauthorized on a transient error.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Dify has no native boolean start-variable type, so a bool requirement the
Builder proposes gets emitted as a `select` — and the LLM often leaves its
`options` empty. An options-less select renders as an empty, unfillable dropdown
in the Builder's test-input form, so the user can never submit test data
(affects every workflow whose requirements include a bool field).
Add _normalize_start_select_variables to the generator postprocess (beside
_normalize_start_file_variables): a `select` start variable with no usable
(non-empty string) options is converted to a `text-input` the user can type
into; a select that declares real options is normalized to those strings and
kept. Idempotent.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Builds failed with an empty graph when the generator LLM wired downstream
references to an HTTP-request node's output as `{#node.response#}`. HTTP-request
nodes expose only {body, status_code, headers, files} — never `response` — and
the reference-repair pass only rewrites to a node's SOLE output, so with four
outputs the ref stayed unresolved: structural validation failed
(runner.py:646 UNRESOLVED_REFERENCE), generate_workflow_graph returned no graph,
and build_nodes produced an empty build ("Couldn't build the workflow").
Add a targeted, unambiguous output-name alias (http-request `response` -> `body`,
the response body) applied in _reconcile_variable_references before the
sole-output fallback, guarded so it only rewrites when `body` is actually
declared. Extensible via _OUTPUT_ALIASES for future known-wrong names.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>